Very large forces can be encountered at the probe tip when the gauge is inserted into a bore. The sensors need to be small to fit into the component, but small sensors and large forces do not always go well together.
|
|
Rotating a gauge in a bore imparts forces that attempt to twist the probe. This can cause positional errors and poor repeatability.
|
![]() (a bore with a key slot or lubrication port can be particularly difficult)
|
|
Solartron Mini Probe’s are double flexures machined from solid material. This is a very difficult process but is done to eliminate the weaknesses present in other types of small fabricated sensors.
|
![]() |
![]() |
Two ‘leaf springs’ working in parallel ensure that the Mini Probe is able to maintain positional accuracy and withstand the forces encountered when rotating a gauge. They are also strong enough to overcome the forces encountered when inserting the gauge into a bore. The choice of the contact tip also plays a very large part in the performance of the probe and a range of user replaceable tips is available to suit various applications and materials.
|
|
Datasheets |
Catalogue Pages | ||
| Mini Probe | 41-44 | ||
| Orbit Network | 67-74 | ||
| See also… | |||
| wigaugeTM wireless bore gauge (WBG) | |||
| Digital Probes | 17-28 | ||
| Understanding Non Repeat | |||
| Complete Catalogue |
|